It adopts strong steel structure, beautiful and durable. The magnetic yoke adopts Baosteel or other oriented magnetic yoke to effectively shield the magnetic field generated by the induction coil. The crimping process is adopted to improve thermal efficiency. The inductor is made of 5mm; 6mm T2 copper cold-rolled tube, and the whole body is treated with insulating paint for three times, and the insulation is wrapped with insulating cloth. The insulation level reaches H level, which can effectively protect the inductor from inter-turn ignition and increase the service life of the coil.
Equipment materials
It adopts strong steel structure, beautiful and durable. The magnetic yoke adopts Baosteel or other oriented magnetic yoke to effectively shield the magnetic field generated by the induction coil. The crimping process is adopted to improve thermal efficiency. The inductor is made of 5mm; 6mm T2 copper cold-rolled tube, and the whole body is treated with insulating paint for three times, and the insulation is wrapped with insulating cloth. The insulation level reaches H level, which can effectively protect the inductor from inter-turn ignition and increase the service life of the coil.
Furnace design
The equipment is reliable in protection, easy to use, and has a low failure rate. It has multiple protection systems, such as water pressure, phase loss, overcurrent, undervoltage, and overvoltage. The operating system adopts hydraulic design with high safety and simple operation. The dual motor design keeps the equipment in a safe state at all times. The harmonic is small, because the rectifier part of the series resonance is always in a fully open state, the harmonic is small, and the pollution to the power grid is small.
Description | Rating |
---|---|
Rated Power (KW) | 800 |
Total Input KVA | 800 |
Input Power Factor | 0.95 |
Input Voltage (Volts) | 400 |
Output Frequency (Hz) | 800 |
Output Voltage (Volts) | 800 |
Melting Temperature (°C) | 1550 |
Nominal Capacity of furnace in Kg for Steel(kg) | 1000 |
Melting Rate for Steel at 1550° C at 3500KW (Kg/Hr) | 1000 |
Lining material | Acid or alkaline material |
Multi-protections: overcurrent, overpressure or underpressure, water pressure, phase loss, furnace leak alarm and water temperature alarm | Yes |