Series Connected Multi Melting System

Technical characteristics
The one-to-two intermediate frequency furnace adopts the "series inverter thyristor intermediate frequency power supply technology". Although the thyristor fully controlled rectifier electric furnace is used, it does not use it for voltage regulation. It only uses it to achieve soft start and act as an electronic switch in the event of a fault to quickly cut off the power supply , In normal operation, the thyristor is always in the fully-on state, so that the grid power supply has a high power factor and reduces harmonic interference. The rectifier control circuit adopts a digital shift trigger circuit. The digital shift trigger circuit has the advantages of good repeatability, good stability, good symmetry, strong anti-interference ability, and convenient debugging. If the digital quantity setting is used, it can still realize remote control.

Description

Advantage 


Efficient

The series inverter adopts a half-bridge circuit, the number of main circuit components is relatively reduced, and there is a high power factor, so it has a higher power.

Good starting characteristics, can start at will under full load and heavy load, the starting success rate is 100%. Improve the power factor to ensure that the power factor reaches 95% at any power.

Constant power output. The power output adopts constant control. During the melting process, when the load and temperature change, the load is always full power output, thereby shortening the melting time.


Has a complete protection and operating status monitoring system

For example, use sensors to obtain signals for incoming line current, voltage, channel current, and voltage, and provide double closed- loop digital circuits for current limiting, voltage limiting, and repeated protection of excessive overvoltage, water temperature and water pressure protection, and so on. Both KK SCR and KP SCR have self-turn-off time protection.


Has a complete detection system

The working temperature of the inverter and filter capacitor is monitored by a temperature switch meter. Once the cooling water temperature exceeds the set value or a water circuit failure occurs, an alarm will be issued and the power supply will be cut off. The power supply cooling water input has a water pressure relay electrical control, and the cooling water output has a temperature switch gauge to monitor undervoltage. If over temperature, an alarm will be issued and the power supply will be cut off.

Parameter

Description    Rating   
Rated Power (KW) 800
Total Input KVA  800
Input Power Factor  0.95
Input Voltage (Volts)  400
Output Frequency (Hz)  800
Output Voltage (Volts)  800
Melting Temperature (°C)  1550
Nominal Capacity of furnace in Kg for Steel(kg)1000
Melting Rate for Steel at 1550° C at 3500KW (Kg/Hr)  1000
Lining materialAcid or alkaline material
Multi-protections: overcurrent, overpressure or underpressure, water pressure, phase loss, furnace leak alarm and water temperature alarmYes